Hydraulic & Pneumatic Systems
Hydraulic power units, cylinders, manifolds, accumulators, pneumatic control and starting-air components.
Hydraulic reliability is decided largely by cleanliness and by the quality of tube and hose installation. Acceptance combines visual inspection, flushing records, pressure tests and functional sequences including safety functions.
Inspection checkpoints
The numbers correspond to the checkpoints marked in the diagram above. Select a point in the diagram to jump to its explanation.
- Tube, hose and fitting installation qualityTube runs are checked for correct bending without flattening, adequate clamping against vibration and stress-free connection. Hoses are checked for type, bend radius, twist and protection from chafing.
- Control valve function and sequencesEach valve is operated in the order given by the hydraulic diagram and the movement of the actuators is observed. Speeds, sequences and interlocks are compared with the functional description.
- System pressure testThe assembled system is pressurised to the specified test pressure and held. Every joint, hose end and weld is examined, and the pressure record is kept with the test certificate.
- Relief and safety device settingsRelief valves are made to lift and their opening pressure is read from a calibrated gauge. Accumulator pre-charge and safety blocks are checked. These devices are the last protection against overload.
- Oil cleanliness after flushingAfter flushing, an oil sample is counted for particles and compared with the specified cleanliness class under ISO 4406. Dirt is the main cause of early failure in hydraulic systems.
Typical documentation
Hydraulic diagram, flushing and cleanliness records, pressure test certificates, component certificates, function test record.